Evaluation of the biochemical oxygen demand in the effluent treatment system of the demonstration unit of the Campus Agrarian Sciences - UNIVASF

Authors

  • COELHO, Suellen Bispo Engenharia Agronômica, UNIVASF
  • GALHARDO, Cristiane Xavier Engenharia Agronômica, UNIVASF
  • MACHADO, Neiton Silva Engenharia Agronômica, UNIVASF
  • FREITAS, Helder Ribeiro Engenharia Agronômica, UNIVASF

Keywords:

Water reuse, effluent, BOD, UASB

Abstract

Basic sanitation is one of the greatest deficiencies in Brazilian rural areas in their different
dimensions. This work was developed in the Demonstration Unit in Renewable Energies, Sanitation
and Technologies of Coexistence with the Semiarid of Agroecological base, aiming to
evaluate the performance of the organic load removal in the sewage treatment plant with reactor
UASB of the UNIVASF Agricultural Sciences Campus. This work aims at the reuse of the
liquid and solid residue generated after treatment, as well as verify if the parameters defined
are in accordance with CONAMA Resolution 430 / 2011. The parameters were investigated:
pH, electrical conductivity, turbidity, temperature and biochemical demand Of oxygen. The preliminary
results indicated a removal of organic load higher than 60% and the other parameters
were in accordance with the legislation.